ED said 2007-01-13 18:48 
 
I have a similar problem. My bike has 54,000 miles. It has been running as strong as ever. Suddenly, it started running very bad and would die at idle. Then it just wouldn´t start. The engine would turn over, but there was no spark to the plugs. Obviously, an electrical problem.

I don´t believe both coils will die at the same time. I have a new, never used CDI unit. I replaced the unit in th ebike with the new unit. Still no spark. I put the old unit back in. I tested the advance pulsar. Everything is within Honda spec. I tested the stator. The specs for the White to Blue reading are 77 to 95 ohms. I got 53. The specs for the Green to White is 315 to 385 ohms. I got 276. All other readings were within Honda specifications.

Am I correct in diagnosing the problem as a bad stator? Changing the stator requires removing the engine from the bike. I don´t want to do this if it isn´t necessary. I can buy a new stator and regulating/rectifier from Electrex. Any opinions on that?
 
 
<<Previous          Answer          Discussion overview          Report spam          Next>>

Comments, questions and answersEnter a comment or answer to this message

You can post your question, answer or comment as a guest. Or enter your e-mail to join the forum and get notifcations of new messages.

 
Title
 
Signature
Optional e-mail
Enter your e-mail to join the forum and get notification of answers and new messages. You can unsubscribe with a single click. Bikez does not display, sell or misuse e-mail addresses.
Message text

Describe technical issues in detail to get quality answers. You can offer or request second-hand parts and equipment as a privat person. Bikez reserves the right to remove any improper or commercial content.
Accept that we store and display the message.